Těšínská 2977/79C, Opava, CZE

+420 553 816 958

info@hansen-electric.cz

Transformer Sets

Transformer sets are designed for the transformation of high voltage to low voltage, for switching and protection of three-phase electrical devices, squirrel cage electric motors or for power supply and protection of an isolated power supply network. The switching mode is controlled according to the needs of the user in the given operation.

 The  Transformer Set  has  got  protection against  explosion Exznak I M2(M1) Ex d ib [iа Ma] I Mb or I M2(M1) Ex d ib [ia] [op is] I M or others as required.

 The product complies with technical requirements for devices determined for use in potentially explosive atmospheres according to Directive 2014/34/EU (NV 116/2016 Sb.). The product also complies with technical requirements of standards according to current requirements and regulations of the country where the device is certified.

Primary side

Transformer sets can be equipped with several versions of the primary side type

SN6 Tinified

SN6

SN17 Tinified

SN17

SN36 Tinified

SN36

SN56 Tinified

SN56

Technical data:

Nominal voltage

3,3/6/10/11 kV IT, 50Hz or 60Hz

Nominal current

according to power output, max. 250A

Nominal short-circuit power

max. 25kА

Nominal off-switching short-circuit current

max. 25kА

Short-circuit resistance, effective value

max. 25kА (3s)

Time for off-switching

<50ms

Maximum number of power inputs

2

Possibility of transit output

max. 2

Transformer VN

The middle part of the transformer set can be supplied in two variants:

Kulaty Zaver

ROUND END

Better heat dissipation

Performance:
up to 2200kVA for secondary voltage 1140V
up to 3150kVA for secondary voltage 3300V

Hranaty Zaver

SQUARE END

Better access to HV transformer

Performance:
up to 1700kVA for secondary voltage 1140V
up to 2100kVA for secondary voltage 3300V

Secondary side

Transformer set can be equipped with different variations of the secondary side depending on the customer's requirements or the needs of the project.

Secondary side types for voltages up to 1140V

SN5 Tinified

SN5

Basic technical parameters:

Nominal voltage

from 400 to 1140VAC, 50/60Hz

Maximum number of power outputs

3

Maximum current of an output

345A

Outputs 42/127/230V

100/300VA

Display ID1 further enables data archiving and data transfer among consecutively connected systems.

SN40 Tinified

SN40

Basic technical parameters:

Nominal voltage

from 400 to 1140VAC, 50/60Hz

Maximum number of power outputs

4

Maximum current of an output

400A

Outputs 42/127/230V

100/300VA

Equipped:

  • without switching outputs
  • Two circuit breakers 630A
  • Two vacuum contactors 630A
  • protected outputs
  • with 2 outputs from each
  • with 2 outputs from each

LCD displej pro zobrazování provozních a poruchových stavů, měřených veličin, pro archivaci a přenos dat mezi návaznými připojenými systémy.

SN12 Tinified

SN12

Basic technical parameters:

Nominal voltage

from 500 to 1140VAC, 50/60Hz

Maximum number of power outputs

10

Equipped:

  • disconnector 500A
  • vacuum contactors 200/450A
  • transformer 127/230V, 5kVA
  • 3 branches
  • max. 10 outputs
  • max. 3 outputs

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.

SN46 Tinified

SN46

Basic technical parameters:

Nominal voltage

from 500 to 1140VAC, 50/60Hz

Maximum number of power outputs

9

Equipped:

  • quick-changing module system
  • disconnector 1000A
  • vacuum contactors 80/200/450A
  • transformer 127/230 V, 5kVA
  • max. 3 modules
  • 2 branches
  • max. 9 outputs
  • max. 2 outputs (1 module)

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.

SN44 Tinified

SN44

Basic technical parameters:

Nominal voltage

from 500 to 1140VAC, 50/60Hz

Maximum number of power outputs

12

Equipped:

  • quick-changing module system
  • disconnector 1000A
  • vacuum contactors 80/200/450A
  • transformer 127/230V, 5kVA
  • max. 4 modules
  • 2 branches
  • max. 12 outputs
  • max. 2 outputs (1 module)

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.

SN42 Tinified

SN42/SN52

Basic technical parameters:

Nominal voltage

from 500 to 1140VAC, 50/60Hz

Maximum number of power outputs

15

Equipped:

  • quick-changing module system
  • disconnector 1000A
  • vacuum contactors 80/200/450A
  • transformer 127/230V, 5kVA
  • circuit breaker 1000A for external switching of the secondary side
  • max. 6 modules
  • 2 branches
  • max. 15 outputs
  • max. 2 outputs (1 module)
  • only for SN52

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.

SN50 Tinified

SN50

Basic technical parameters:

Nominal voltage

500/660VAC, 50Hz

Total nominal current

2 x 540A

Maximum number of power outputs

2

Outputs 127/230V

2 x 6/3A

Equipped:

  • frequency invertor 660V
  • transformer 127/230V
  • closed water cooling circuit
  • engine braking
  • max. 2
  • 2 x 6/3A
  • 12l/min
  • resistor with water cooling

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.

Secondary side types for 3300V voltage

SN18 Tinified

SN18

Basic technical parameters:

Nominal voltage

3300VAC, 50/60Hz

Maximum number of power outputs

2

Maximum current of an output

345A

Outputs 42/127/230V

100/300VA

Display ID1 further enables data archiving and data transfer among consecutively connected systems.

SN11 Tinified

SN11

Basic technical parameters:

Nominal voltage

3300VAC, 50/60Hz

Maximum number of power outputs

4

Equipped:

  • quick-changing module system
  • earthing switch 3,6kV
  • vacuum contactors 450A
  • transformer 127/230V, 5kVA
  • max. 4 modules
  • 4
  • max. 4 outputs (reversible)
  • max. 2 outputs

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.

SN47 Tinified

SN47

Basic technical parameters:

Nominal voltage

3300VAC, 50/60Hz

Maximum number of power outputs

6

Vybavení:

  • quick-changing module system
  • earthing switch 3,6kV
  • vacuum contactors 450A
  • transformer 127/230V, 5kVA
  • max. 6 modules
  • 4
  • max. 6 outputs (reversible)
  • max. 2 outputs (1 module)

The Load Center is equipped with an industrial PC which serves for monitoring and parameterization of digital protections of the set, saving parameters of the protections, measuring values, operating and faulty conditions. All the information is possible to transmit by I.S. separators to a remote working place. The Industrial PC is equipped with I.S. keyboard, I.S. mouse and 12” screen. It is possible to add optical output and voice communication (VoIP) via Ethernet.